Thread (1354 messages) 1354 messages, 168 authors, 2017-04-12

[PATCH 4/13] ALSA: oxygen: Delete an unnecessary check before the function call "snd_pcm_suspend"

From: SF Markus Elfring <hidden>
Date: 2015-01-04 13:00:33
Also in: alsa-devel, lkml
Subsystem: c-media cmi8788 driver, sound, the rest · Maintainers: Clemens Ladisch, Jaroslav Kysela, Takashi Iwai, Linus Torvalds

From: Markus Elfring <redacted>
Date: Sat, 3 Jan 2015 17:37:28 +0100

The snd_pcm_suspend() function tests whether its argument is NULL and then
returns immediately. Thus the test around the call is not needed.

This issue was detected by using the Coccinelle software.

Signed-off-by: Markus Elfring <redacted>
---
 sound/pci/oxygen/oxygen_lib.c | 3 +--
 1 file changed, 1 insertion(+), 2 deletions(-)
diff --git a/sound/pci/oxygen/oxygen_lib.c b/sound/pci/oxygen/oxygen_lib.c
index b67e306..61a62c0 100644
--- a/sound/pci/oxygen/oxygen_lib.c
+++ b/sound/pci/oxygen/oxygen_lib.c
@@ -736,8 +736,7 @@ static int oxygen_pci_suspend(struct device *dev)
 	snd_power_change_state(card, SNDRV_CTL_POWER_D3hot);
 
 	for (i = 0; i < PCM_COUNT; ++i)
-		if (chip->streams[i])
-			snd_pcm_suspend(chip->streams[i]);
+		snd_pcm_suspend(chip->streams[i]);
 
 	if (chip->model.suspend)
 		chip->model.suspend(chip);
-- 
2.2.1