Re: [PATCH 2/6] Input: elantech - use firmware provided x, y ranges

From: JJ Ding <hidden>
Date: 2011-08-19 09:44:58
Also in: lkml

Hi Dmitry,

Sorry for late reply. I missed this one somehow.

On Thu, 18 Aug 2011 00:47:56 -0700, Dmitry Torokhov [off-list ref] wrote:
On Thu, Aug 18, 2011 at 09:57:05AM +0800, JJ Ding wrote:
quoted
+
+		i = (etd->fw_version > 0x020800 &&
+		     etd->fw_version < 0x020900) ? 1 : 2;
+		*x_max = (etd->capabilities[1] - i) * 64;
+		*y_max = (etd->capabilities[2] - i) * 64;
+		*y_2ft_max = (*y_max - i) * 64 / 4;
Hmm, we should have the same range for ST and MT data and scale MT data
if it has lower resolution to match ST.
So I should just remove y_2ft_max and those ETP_2FT_XXXX in elantech.h,
and do the scale in elantech_report_absolute_v2?

If so, I will create another patch for this change.

Is this OK with you?

Thanks.
jj
Thanks.

-- 
Dmitry