On Fri, Nov 20, 2020 at 02:43:11AM +0100, Marek Behun wrote:
Hi Andrew,
On Fri, 20 Nov 2020 02:29:06 +0100
Andrew Lunn [off-list ref] wrote:
quoted
quoted
+ if (speed >= 2500 && port > 0 && port < 9)
+ return -EOPNOTSUPP;
Maybe i'm missing something, but it looks like at this point you can
call
return mv88e6xxx_port_set_speed_duplex(chip, port, speed, true, true, duplex);
He can't. That function does not support speed 5000. You can't simply
add it, because it clashes with register value for speed 2500 on
previous switches (Peridot, Topaz).
Amethyst reg val Peridot + Topaz reg val
2500 SPD_1000 | ALT_BIT SPD_10000 | ALT_BIT
5000 SPD_10000 | ALT_BIT not supported
10000 SPD_UNFORCED SPD_UNFORCED
Hi Marek
O.K, as i said, i might be missing something :-)
I think a comment would be nice, pointing this out. Otherwise somebody
might try refactoring it, and make the same mistake!
Andrew