Thread (79 messages) 79 messages, 6 authors, 2024-07-08
STALE711d
Revisions (11)
  1. v5 [diff vs current]
  2. v6 [diff vs current]
  3. v7 [diff vs current]
  4. v8 [diff vs current]
  5. v12 [diff vs current]
  6. v13 current
  7. v14 [diff vs current]
  8. v15 [diff vs current]
  9. v15 [diff vs current]
  10. v16 [diff vs current]
  11. v17 [diff vs current]

[PATCH net-next v13 07/15] net: stmmac: dwmac-loongson: Init ref and PTP clocks rate

From: Yanteng Si <hidden>
Date: 2024-05-29 10:20:02
Subsystem: networking drivers, stmmac ethernet driver, the rest · Maintainers: Andrew Lunn, "David S. Miller", Eric Dumazet, Jakub Kicinski, Paolo Abeni, Linus Torvalds

Reference and PTP clocks rate of the Loongson GMAC devices is 125MHz.
(So is in the GNET devices which support is about to be added.) Set
the respective plat_stmmacenet_data field up in accordance with that
so to have the coalesce command and timestamping work correctly.

Signed-off-by: Feiyang Chen <redacted>
Signed-off-by: Yinggang Gu <redacted>
Signed-off-by: Yanteng Si <redacted>
---
 drivers/net/ethernet/stmicro/stmmac/dwmac-loongson.c | 3 +++
 1 file changed, 3 insertions(+)
diff --git a/drivers/net/ethernet/stmicro/stmmac/dwmac-loongson.c b/drivers/net/ethernet/stmicro/stmmac/dwmac-loongson.c
index ad3f44440963..e725c59c6c98 100644
--- a/drivers/net/ethernet/stmicro/stmmac/dwmac-loongson.c
+++ b/drivers/net/ethernet/stmicro/stmmac/dwmac-loongson.c
@@ -35,6 +35,9 @@ static void loongson_default_data(struct plat_stmmacenet_data *plat)
 	/* Disable RX queues routing by default */
 	plat->rx_queues_cfg[0].pkt_route = 0x0;
 
+	plat->clk_ref_rate = 125000000;
+	plat->clk_ptp_rate = 125000000;
+
 	/* Default to phy auto-detection */
 	plat->phy_addr = -1;
 
-- 
2.31.4