Thread (41 messages) 41 messages, 5 authors, 2009-05-31

Re: [PATCH 4/4 v2] netdev: bfin_mac: add Blackfin MII bus to platform bus to allow DSA access

From: David Miller <davem@davemloft.net>
Date: 2009-05-29 22:49:59

From: Mike Frysinger <redacted>
Date: Fri, 29 May 2009 09:41:48 -0400
From: Graf Yang <redacted>

When we register the MII bus to the platfrom bus, the Distributed Switch
Architecture can hook in transparently.

Signed-off-by: Graf Yang <redacted>
Signed-off-by: Mike Frysinger <redacted>
Applied to net-next-2.6
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help