On 09/01/2011 04:41 AM, LiuShuo wrote:
After doing some tests, I found that the elbc controller can read/write
4k with one command
if we insert a FIR_OP_NOP between first half reading/wring and second
half reading/writing.(delay for something ?)
From the docs:
A NOP instruction that appears in FIR ahead of the last instruction
is executed with the timing of a regular command instruction, but
neither LFCLE nor LFWE are asserted. Thus a NOP instruction may be
used to insert a pause matching the time taken for a regular command
write.
So the NOP does generate a delay. Would be nice to know exactly why
it's required.
Have you tried doing this under load with parallel NOR activity? With
CE-don't-care operation, during the times when CE is not asserted, does
it matter what happens with CLE/ALE/RE? These signals could be driven
for another chipselect during that time.
-Scott