RE: [Bluez-devel] Qualification Testing
From: Stephen Crane <hidden>
Date: 2003-05-12 16:37:29
Hi Daryl, On Thu, 2003-05-08 at 03:18, Daryl Van Vorst wrote:
Steve,quoted
quoted
2.) There appears to be a problem handling continuation states. Handling continuation state is optional. We foundthat if thequoted
querying device sends a maximum byte count of 100, thecontinutationquoted
state worked fine. But if the querying device sent a maximum byte count of 8, the continuation state doesn't work (thecontinuation flagquoted
wasn't recognized in the next packet). I can dig up anexample log ifquoted
it would help.Yeah it would be good to get a log. I imagine 8-bytes is pretty close to the minimum size.
Would it be possible to get an hcidump from the machine on which the SDP server is running? (I am interested to see what data the SDP server is actually returning.) (hcidump -x -w file.dump -i hci0) Thanks, Steve -- Stephen Crane, Rococo Software Ltd. http://www.rococosoft.com steve.crane@rococosoft.com +353-1-6601315 (ext 209) ------------------------------------------------------- Enterprise Linux Forum Conference & Expo, June 4-6, 2003, Santa Clara The only event dedicated to issues related to Linux enterprise solutions www.enterpriselinuxforum.com _______________________________________________ Bluez-devel mailing list Bluez-devel@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/bluez-devel