On Oct 20 Jarod Wilson wrote:
firewire-net:
- set min/max_mtu
- remove fwnet_change_mtu
[...]
quoted hunk ↗ jump to hunk
--- a/drivers/firewire/net.c
+++ b/drivers/firewire/net.c
[...]
quoted hunk ↗ jump to hunk
@@ -1478,9 +1467,10 @@ static int fwnet_probe(struct fw_unit *unit,
* Use the RFC 2734 default 1500 octets or the maximum payload
* as initial MTU
*/
- max_mtu = (1 << (card->max_receive + 1))
- - sizeof(struct rfc2734_header) - IEEE1394_GASP_HDR_SIZE;
- net->mtu = min(1500U, max_mtu);
+ net->max_mtu = (1 << (card->max_receive + 1))
+ - sizeof(struct rfc2734_header) - IEEE1394_GASP_HDR_SIZE;
+ net->mtu = min(1500U, net->max_mtu);
+ net->min_mtu = ETH_MIN_MTU;
/* Set our hardware address while we're at it */
ha = (union fwnet_hwaddr *)net->dev_addr;
Please preserve the current behavior, i.e. do not enforce any particular
upper bound. (Especially none based on the local link layer controller's
max_receive parameter.)
BTW, after having read RFC 2734, RFC 3146, and the code, I am convinced
that net->mtu should be initialized to 1500, not less. But such a change
should be done in a separate patch.
--
Stefan Richter
-======----- =-=- =-==-
http://arcgraph.de/sr/