Thread (18 messages) 18 messages, 5 authors, 2018-08-01

Re: [PATCH v3 5/9] powerpc/traps: Print signal name for unhandled signals

From: Segher Boessenkool <hidden>
Date: 2018-08-01 07:57:54
Also in: lkml

On Wed, Aug 01, 2018 at 12:03:50AM -0700, Joe Perches wrote:
On Wed, 2018-08-01 at 08:37 +0200, Christophe LEROY wrote:
quoted
Le 31/07/2018 à 16:50, Murilo Opsfelder Araujo a écrit :
I would suggest to instead use a function like this:

static const char *signame(int signr)
{
	if (signr == SIGBUS)
		return "bus error";
	if (signr == SIGFPE)
		return "floating point exception";
	if (signr == SIGILL)
		return "illegal instruction";
	if (signr == SIGILL)
		return "segfault";
	if (signr == SIGTRAP)
		return "unhandled trap";
	return "unknown signal";
}
trivia:

Unless the if tests are ordered most to least likely,
perhaps it would be better to use a switch/case and
let the compiler decide.
That would also show there are two entries for SIGILL (here and in the
original patch), one of them very wrong.

Check the table with psignal or something?


Segher
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree