On Thu, Feb 8, 2024 at 1:44 PM Claudiu [off-list ref] wrote:
From: Claudiu Beznea <claudiu.beznea.uj@bp.renesas.com>
Update CPG #power-domain-cells = <1> and move all the IPs to be part of the
always on power domain as the driver has been modified to support multiple
power domains.
Signed-off-by: Claudiu Beznea <claudiu.beznea.uj@bp.renesas.com>
quoted hunk ↗ jump to hunk
--- a/arch/arm64/boot/dts/renesas/r9a07g054.dtsi
+++ b/arch/arm64/boot/dts/renesas/r9a07g054.dtsi
@@ -238,7 +238,7 @@ mtu3: timer@10001200 {
"tgia8", "tgib8", "tgic8", "tgid8",
"tciv8", "tciu8";
clocks = <&cpg CPG_MOD R9A07G054_MTU_X_MCK_MTU3>;
- power-domains = <&cpg>;
+ power-domains = <&cpg R9A07G054_PD_ALWAYS_ON>;
This should be R9A07G054_PD_MTU, but that domain is not yet supported
by the driver. Instead of adding incorrect hardware descriptions,
I'd rather defer this until all domains are handled by the driver.
resets = <&cpg R9A07G054_MTU_X_PRESET_MTU3>;
#pwm-cells = <2>;
status = "disabled";
Gr{oetje,eeting}s,
Geert
--
Geert Uytterhoeven -- There's lots of Linux beyond ia32 -- geert@linux-m68k.org
In personal conversations with technical people, I call myself a hacker. But
when I'm talking to journalists I just say "programmer" or something like that.
-- Linus Torvalds