Thread (24 messages) flat view 24 messages, 3 authors, 2020-07-08

[v4,5/7] thermal: mediatek: mt8183: fix bank number settings

From: Michael Kao <hidden>
Date: 2020-03-23 12:15:52
Also in: linux-devicetree, linux-mediatek, linux-pm, lkml
Subsystem: the rest, thermal · Maintainers: Linus Torvalds, Rafael J. Wysocki, Daniel Lezcano

MT8183_NUM_ZONES should be set to 1
because MT8183 doesn't have multiple banks.

Fixes: a4ffe6b52d27 ("thermal: mediatek: add support for MT8183")
Signed-off-by: Michael Kao <redacted>
Signed-off-by: Hsin-Yi Wang <redacted>
---
 drivers/thermal/mtk_thermal.c | 5 ++++-
 1 file changed, 4 insertions(+), 1 deletion(-)
diff --git a/drivers/thermal/mtk_thermal.c b/drivers/thermal/mtk_thermal.c
index 76e30603d4d5..6b7ef1993d7e 100644
--- a/drivers/thermal/mtk_thermal.c
+++ b/drivers/thermal/mtk_thermal.c
@@ -211,6 +211,9 @@ enum {
 /* The total number of temperature sensors in the MT8183 */
 #define MT8183_NUM_SENSORS	6
 
+/* The number of banks in the MT8183 */
+#define MT8183_NUM_ZONES               1
+
 /* The number of sensing points per bank */
 #define MT8183_NUM_SENSORS_PER_ZONE	 6
 
@@ -497,7 +500,7 @@ static const struct mtk_thermal_data mt7622_thermal_data = {
  */
 static const struct mtk_thermal_data mt8183_thermal_data = {
 	.auxadc_channel = MT8183_TEMP_AUXADC_CHANNEL,
-	.num_banks = MT8183_NUM_SENSORS_PER_ZONE,
+	.num_banks = MT8183_NUM_ZONES,
 	.num_sensors = MT8183_NUM_SENSORS,
 	.vts_index = mt8183_vts_index,
 	.cali_val = MT8183_CALIBRATION,
-- 
2.18.0
_______________________________________________
linux-arm-kernel mailing list
linux-arm-kernel@lists.infradead.org
http://lists.infradead.org/mailman/listinfo/linux-arm-kernel