Hello Miquel,
On Tue, 22 Jan 2019 20:16:35 +0100, Miquel Raynal wrote:
quoted
Do we really need different compatible strings for those ? I assume the
IP block is exactly the same for the two PHYs, right ? If so, we should
use the same compatible string.
For what I understand, the PHYs are different. At least this is how
they are described in the specification. I can list at least two
differences visible in the register set:
* one has OTG registers, the other does not.
* one has charger detection capabilities (and registers), the other
does not.
OK, then indeed it makes sense to have two different compatible strings.
quoted
Those registers are contiguous to the register range of the PHY itself.
What was the criteria used to decide that we need two separate DT nodes
for these ?
Because this area contains a bunch of registers, most of them are
there to manage the PHY, but others are related to the USB controller
(ie. a software reset). I know the current USB controller driver does
not access this area but what if one day we decide to do it?
OK, if indeed this register area contains register used both for the
PHY and for something else, your DT representation makes sense.
Thanks for those clarifications!
Thomas
--
Thomas Petazzoni, CTO, Bootlin
Embedded Linux and Kernel engineering
https://bootlin.com
_______________________________________________
linux-arm-kernel mailing list
linux-arm-kernel@lists.infradead.org
http://lists.infradead.org/mailman/listinfo/linux-arm-kernel