Hello Mike,
On 07/01/2014 07:29 PM, Mike Turquette wrote:
Quoting Javier Martinez Canillas (2014-06-26 11:15:36)
quoted
Like most clock drivers, the Maxim 77686 PMIC clock binding
follows the convention that the "#clock-cells" property is
used to specify the number of cells in a clock provider.
But the binding document is not clear enough that it shall
be set to 1 since the PMIC support multiple clocks outputs.
Also, explain that the clocks identifiers are defined in a
header file that can be included by Device Tree source with
client nodes to avoid using magic numbers.
Signed-off-by: Javier Martinez Canillas <redacted>
Reviewed-by: Krzysztof Kozlowski <redacted>
Reviewed-by: Doug Anderson <dianders@chromium.org>
Looks good to me.
Regards,
Mike
Thanks a lot, an Acked-by or Reviewed-by tags for this patch and 03/14 will be
great as well so I can carry those on the next version of the series.
Best regards,
Javier