Thread (42 messages) flat view 42 messages, 8 authors, 2014-07-02

[PATCH v5 05/14] clk: Add generic driver for Maxim PMIC clocks

From: Javier Martinez Canillas <hidden>
Date: 2014-06-30 16:00:15
Also in: linux-devicetree, linux-samsung-soc, lkml

Hello Russell,

Thanks a lot for your suggestion.

On 06/30/2014 01:35 PM, Russell King - ARM Linux wrote:
On Mon, Jun 30, 2014 at 12:58:57PM +0200, Javier Martinez Canillas wrote:
quoted
quoted
quoted
+       if (!max_gen->lookup)
+               return ERR_PTR(-ENOMEM);
+
+       max_gen->lookup->con_id = hw->init->name;
Also IMO,  init->name should be over-written if name is provided in DT,
otherwise generic "clock-output-names" property will go futile,
perhaps it should be done before clk_register.
Even though Documentation/devicetree/bindings/clock/clock-bindings.txt says that
the "clock-output-names" property is optional I agree with you that will be
better to support it. So I'll add it on the next version as well.
However, remember that con_id is the _DEVICE_ specific connection name,
not the _CLOCK_ name.  You will get a NAK from me if you violate this
rule.
Yes I know that con_id is the device specific connection name that is set by the
consumers using the "clock-names" property. But AFAIU the clk_lookup structs
added by clockdev_add() are only used by legacy non-DT drivers which don't set
their clock names and instead is the clock driver the one that set con_id to the
struct clk_init_data .name field.

I see that other drivers do the same, is that wrong as well? What value should
have con_id when registering clkdevs for legacy non-DT drivers?

DT enabled drivers whose devices define their "clock-names" are not affected by
this since the clock lookup is made by matching OF "clock-names" property + and
index.

Best regards,
Javier