Re: [RFC PATCH v2 3/5] librte_ether: add API's for VF management
From: Iremonger, Bernard <hidden>
Date: 2016-09-23 17:02:20
Hi Thoms
-----Original Message----- From: Thomas Monjalon [mailto:thomas.monjalon@6wind.com] Sent: Friday, September 23, 2016 2:15 PM To: Richardson, Bruce <redacted>; Iremonger, Bernard [off-list ref] Cc: dev@dpdk.org; Jerin Jacob <redacted>; Shah, Rahul R [off-list ref]; Lu, Wenzhuo [off-list ref]; azelezniak [off-list ref] Subject: Re: [dpdk-dev] [RFC PATCH v2 3/5] librte_ether: add API's for VF management 2016-09-23 09:53, Richardson, Bruce:quoted
From: Thomas Monjalon [mailto:thomas.monjalon@6wind.com]quoted
2016-09-23 10:20, Bruce Richardson:quoted
On Thu, Sep 22, 2016 at 07:04:37PM +0200, Thomas Monjalon wrote:quoted
2016-09-15 16:46, Iremonger, Bernard:quoted
quoted
quoted
quoted
Do we really need to expose VF specific functions here? It can be generic(PF/VF) function indexed only throughport_id.quoted
quoted
quoted
quoted
quoted
quoted
(example: as rte_eth_dev_set_vlan_anti_spoof(uint8_t port_id, uint8_t on)) For instance, In Thunderx PMD, We are not exposing a separate port_id for PF. We only enumerate 0..N VFs as 0..N ethdev port_idOur intention with this patch is to control the VF from the PF. The following librte_ether functions already work in a similarway:quoted
quoted
quoted
quoted
quoted
rte_eth_dev_set_vf_rxmode(uint8_t port_id, uint16_t vf, uint16_t rx_mode, uint8_t on) rte_eth_dev_set_vf_rx(uint8_t port_id, uint16_t vf, uint8_t on) rte_eth_dev_set_vf_tx(uint8_t port_id, uint16_t vf, uint8_t on) int rte_eth_set_vf_rate_limit(uint8_t port_id, uint16_t vf, uint16_t tx_rate, uint64_t q_msk)I have a bad feeling with these functions dedicated to VF from PF. Are we sure there is no other way? I mean we just need to know the VF with a port ID.When the VF is used in a VM the port ID of the VF is not visible tothe PF.quoted
quoted
quoted
I don't think there is another way to do this.I don't understand why we could not assign a port id to the VF from the host instead of having the couple PF port id / VF id. Can we enumerate all the VFs associated to a PF? Then can we allocate them a port id in the array rte_eth_devices?Hi Thomas, The VF is not a port visible to DPDK, though, so it shouldn't have a port id IMHO. DPDK can't actually do anything with it.You say the contrary below.Well, yes and no. The driver can manipulate things for the VF, but DPDKdoesn't actually have a device that corresponds to the VF. There are no PCI bar mappings for it, DPDK can't do RX and TX with it etc.? Very good point. There are only few ethdev functions which are supported by every drivers, like Rx/Tx and would not be available for VF from PF interface.quoted
quoted
quoted
The PCI device for the VF is likely passed through to a different VM and being used there. Unfortunately, the VF still needs certain things done for it by the PF, so if the PF is under DPDK control, it needs to provide the functionality to assist the VF.Why not have a VF_from_PF driver which does the mailbox things? So you can manage the VF from the PF with a simple port id. It really seems to be the cleanest design to me.While I see your point, and it could work, I just want to be sure that we areok with the results of that. Suppose we do create ethdevs for the VFs controlled by the PF. Does the new VF get counted in the rte_eth_dev_count() value (I assume yes)? How are apps meant to use the port? Do they have to put in a special case when iterating through all the port ids to check that it's not a pseudo port that can't do anything. None of the standard ethdev calls from an app will work on it, you can't configure nb rx/tx queues on it, you can't start or stop it, you can't do rx or tx on it, etc, etc. Yes these devices would be special because their supported API would be quite different. I was thinking that in the future you could add most of the configuration functions through the VF mailbox. But the Intel mailbox currently support only some special configurations which are not supported by other devices even its own VF device (except setting MAC address). And when I read "set drop enable bit in the VF split rx control register", it becomes clear it is really specific and has nothing to do in the generic ethdev API. That's why it is a NACK. When we want to use these very specific features we are aware of the underlying device and driver. So we can directly include a header from the driver. I suggest to retrieve a handler for the device which is not a port id and will allow to call ixgbe functions directly. It could be achieved by adding an ethdev function like discussed here: http://dpdk.org/ml/archives/dev/2016-September/047392.html
I have been reading the net/vhost mail thread above. The following quote is from this thread. "It means I would be in favor of introducing API in drivers for very specific features." At present all the PMD functions are accessed through the eth_dev_ops structure, there are no PMD API's. Is your proposal to add API(s) to the DPDK ixgbe PMD (similar to a driver ioctl API) which can be accessed through a generic API in the ethdev? What will this generic API look like? Regards, Bernard.