Re: [PATCH net-next v3 0/2] net: dsa: mxl-gsw1xx: reset the switch through reset-gpios

From
Joseph Telaak <hidden>
Date
2026-11-13 22:17:05
Also in
linux-devicetree, lkml
Reply to
Andrew Lunn, 2026-11-13
On Fri, Nov 13, 2026 at 11:05:55PM +0100, Andrew Lunn wrote:
quoted
The driver does what is described in the device tree. Ie. boot firmware
applying a non-default PHY addresses should just say so in the DT passed
to Linux imho.
And this is what i was wondering about. Is it the DT which is wrong,
or the driver?
The DT. The driver assumes nothing about the addresses; the board's
device tree described the PHYs at their power-on addresses, 0 to 2.

The bootloader is GL.iNet's U-Boot, which is only available as a binary,
so I can't say why it moves them. On every boot it pulses the switch's
reset GPIO, sets up the switch, and leaves the GPHY of port N at MDIO
address N + 1, through the PHY_ADDR registers Daniel listed.

GL's own firmware deals with it the same way this series does: its
Linux driver pulses the reset GPIO at boot, and under that firmware
PHY_ADDR_0 to PHY_ADDR_3 read back 0 to 3.

I'm testing the other way now, with the PHYs described at 1 to 3 and no
reset from Linux. If that works on warm and cold boots, this series
isn't needed and I'll drop it. You were also right that 82e2c7db0830
had no place in the cover letter.