Hi Vladimir, Andrew, Woojung,
Hi Vladimir,quoted
On Fri, Sep 22, 2023 at 03:31:03PM +0200, Lukasz Majewski wrote:quoted
This patch series provides support for HSR HW offloading in KSZ9477 switch IC. To test this feature: ip link add name hsr0 type hsr slave1 lan1 slave2 lan2 supervision 45 version 1 ip link set dev lan1 up ip link set dev lan2 up ip a add 192.168.0.1/24 dev hsr0 ip link set dev hsr0 up To remove HSR network device: ip link del hsr0 To test if one can adjust MAC address: ip link set lan2 address 00:01:02:AA:BB:CC It is also possible to create another HSR interface, but it will only support HSR is software - e.g. ip link add name hsr1 type hsr slave1 lan3 slave2 lan4 supervision 45 version 1 Test HW: Two KSZ9477-EVB boards with HSR ports set to "Port1" and "Port2". Performance SW used: nuttcp -S --nofork nuttcp -vv -T 60 -r 192.168.0.2 nuttcp -vv -T 60 -t 192.168.0.2 Code: v6.6.0-rc2+ Linux net-next repository SHA1: 5a1b322cb0b7d0d33a2d13462294dc0f46911172 Tested HSR v0 and v1 Results: With KSZ9477 offloading support added: RX: 100 Mbps TX: 98 Mbps With no offloading RX: 63 Mbps TX: 63 MbpsReviewed-by: Vladimir Oltean <vladimir.oltean@nxp.com> Thanks!I hope, that it will find its way to net-next soon :-).
I'm a bit puzzled with this patch series - will it be pulled directly to net-next [1] or is there any other (KSZ maintainer's?) tree to which it will be first pulled and then PR will be send to net-next? Thanks in advance for the clarification.
Thanks for your help and patience.
Links: [1] - https://git.kernel.org/pub/scm/linux/kernel/git/netdev/net-next.git/log/
Best regards, Lukasz Majewski -- DENX Software Engineering GmbH, Managing Director: Erika Unter HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-59 Fax: (+49)-8142-66989-80 Email: lukma@denx.de
Best regards, Lukasz Majewski -- DENX Software Engineering GmbH, Managing Director: Erika Unter HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-59 Fax: (+49)-8142-66989-80 Email: lukma@denx.de