On Tue, Mar 22, 2022 at 01:21:05AM +0100, Andrew Lunn wrote:
quoted
quoted
The use case is generic i.e. require separate handle to internal SGMII
and external Phy so would prefer this new DT convention is
standardized or we discuss possible approaches on how to handle
both phys and not add it as vendor specific property in the first
place.
IMO, you should use 'phys' for the internal PCS phy. That's aligned with
other uses like PCIe, SATA, etc. (there is phy h/w that will do PCS,
PCIe, SATA). 'phy-handle' is for the ethernet PHY.
We need to be careful here, because the PCS can have a well defined
set of registers accessible over MDIO. Generic PHY has no
infrastructure for that, it is all inside phylink which implements the
pcs registers which are part of 802.3.
Using the phy binding doesn't mean you have to use the kernel's 'generic
PHY' subsytem.
But if there's a need to do something different then propose something
that handles the complex cases.
I also wonder if a PCS might actually have a generic PHY embedded in
it to provide its lower interface?
That's just looking at a single PCS/PHY block the other way around.
PCS is part of the PHY or the PHY is part of PCS? I don't think that
matters too much. I think the 2 cases would be it's all 1 block or 2
blocks.
Rob