The use case is generic i.e. require separate handle to internal SGMII
and external Phy so would prefer this new DT convention is 
standardized or we discuss possible approaches on how to handle
both phys and not add it as vendor specific property in the first 
place.
IMO, you should use 'phys' for the internal PCS phy. That's aligned with 
other uses like PCIe, SATA, etc. (there is phy h/w that will do PCS, 
PCIe, SATA). 'phy-handle' is for the ethernet PHY.
We need to be careful here, because the PCS can have a well defined
set of registers accessible over MDIO. Generic PHY has no
infrastructure for that, it is all inside phylink which implements the
pcs registers which are part of 802.3.

I also wonder if a PCS might actually have a generic PHY embedded in
it to provide its lower interface?