Re: mv88e6240 configuration broken for B850v3
flat view
From: Martyn Welch <hidden>
Date: 2021-12-06 18:37:50
On Mon, 2021-12-06 at 20:31 +0200, Vladimir Oltean wrote:
On Mon, Dec 06, 2021 at 06:26:25PM +0000, Martyn Welch wrote:quoted
On Mon, 2021-12-06 at 17:44 +0000, Martyn Welch wrote:quoted
On Fri, 2021-12-03 at 17:25 +0100, Andrew Lunn wrote:quoted
quoted
Hi Andrew,Adding Russell to Cc:quoted
I'm currently in the process of updating the GE B850v3 [1] to run a newer kernel than the one it's currently running.Which kernel exactly. We like bug reports against net-next, or at least the last -rc.I tested using v5.15-rc3 and that was also affected.I've just tested v5.16-rc4 (sorry - just realised I previously wrote v5.15-rc3, it was v5.16-rc3...) and that was exactly the same.Just to clarify: you're saying that you're on v5.16-rc4 and that if you revert commit 3be98b2d5fbc ("net: dsa: Down cpu/dsa ports phylink will control"), the link works again?
Correct
It is a bit strange that the external ports negotiate at 10Mbps/Full, is that the link speed you intend the ports to work at?
Yes, that's 100% intentional due to what's connected to to those ports and the environment it works in. Martyn