Thread (17 messages) 17 messages, 3 authors, 2021-09-30

Re: Lockup in phy_probe() for MDIO device (Broadcom's switch)

From: "Russell King (Oracle)" <linux@armlinux.org.uk>
Date: 2021-09-30 12:30:24

On Thu, Sep 30, 2021 at 02:14:54PM +0200, Rafał Miłecki wrote:
On 30.09.2021 13:44, Russell King (Oracle) wrote:
quoted
On Thu, Sep 30, 2021 at 01:29:33PM +0200, Rafał Miłecki wrote:
quoted
On 30.09.2021 12:40, Russell King (Oracle) wrote:
quoted
In phy_probe, can you add:

	WARN_ON(!(phydev->mdio.flags & MDIO_DEVICE_FLAG_PHY));

just to make sure we have a real PHY device there please? Maybe also
print the value of the flags argument.

MDIO_DEVICE_FLAG_PHY is set by phy_create_device() before the mutex is
initialised, so if it is set, the lock should be initialised.

Maybe also print mdiodev->flags in mdio_device_register() as well, so
we can see what is being registered and the flags being used for that
device.

Could it be that openwrt is carrying a patch that is causing this
issue?
I don't think there is any OpenWrt patch affecting that.

MDIO_DEVICE_FLAG_PHY seems to be missing.
Right, so the mdio device being registered is a non-PHY MDIO device.
It doesn't have a struct phy_device around it - and so any access
outside of the mdio_device is an out-of-bounds access.
I can confirm that.

of_mdiobus_register() iterates over node children. It calls
of_mdiobus_child_is_phy() for the /mdio-mux@18003000/mdio@200/switch@0
and that returns 0. It results in calling of_mdiobus_register_device().

So we have MDIO device as expected. It's not a PHY device.
Right - because it's a switch device - identified as having a
compatible but without having a PHY-like compatible.

	compatible = "brcm,bcm53125";

This will be created by mdio_device_create(), which will not have
its bus_match method populated. So the only way a driver registered
on the MDIO bus_type can match is via the DT-based matching I've
previously mentioned.
quoted
Consequently, phylib should not be matching this device. The only
remaining way I can see that this could happen is if a PHY driver has
an OF compatible, which phylib drivers should never have.
It's actually OpenWrt's downstream swconfig-based b53 driver that
matches this device.

I'm confused as downstream b53_mdio.c calls phy_driver_register(). Why
does it match MDIO device then? I thought MDIO devices should be
matches only with drivers using mdio_driver_register().
Note that I've no idea what he swconfig-based b53 driver looks like,
I don't have the source for that to hand.

If it calls phy_driver_register(), then it is registering a driver for
a MDIO device wrapped in a struct phy_device. If this driver has a
.of_match_table member set, then this is wrong - the basic rule is

	PHY drivers must never match using DT compatibles.

because this is exactly what will occur - it bypasses the check that
the mdio_device being matched is in fact wrapped by a struct phy_device,
and we will access members of the non-existent phy_device, including
the "uninitialised" mutex.

If the swconfig-based b53 driver does want to bind to a phy_device based
DT node, then it needs to match using either a custom .match_phy_device
method in the PHY driver, or it needs to match using the PHY IDs.

-- 
RMK's Patch system: https://www.armlinux.org.uk/developer/patches/
FTTP is here! 40Mbps down 10Mbps up. Decent connectivity at last!
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help