Re: Lockup in phy_probe() for MDIO device (Broadcom's switch)
From: "Russell King (Oracle)" <linux@armlinux.org.uk>
Date: 2021-09-30 11:44:23
On Thu, Sep 30, 2021 at 01:29:33PM +0200, Rafał Miłecki wrote:
On 30.09.2021 12:40, Russell King (Oracle) wrote:quoted
In phy_probe, can you add: WARN_ON(!(phydev->mdio.flags & MDIO_DEVICE_FLAG_PHY)); just to make sure we have a real PHY device there please? Maybe also print the value of the flags argument. MDIO_DEVICE_FLAG_PHY is set by phy_create_device() before the mutex is initialised, so if it is set, the lock should be initialised. Maybe also print mdiodev->flags in mdio_device_register() as well, so we can see what is being registered and the flags being used for that device. Could it be that openwrt is carrying a patch that is causing this issue?I don't think there is any OpenWrt patch affecting that. MDIO_DEVICE_FLAG_PHY seems to be missing.
Right, so the mdio device being registered is a non-PHY MDIO device. It doesn't have a struct phy_device around it - and so any access outside of the mdio_device is an out-of-bounds access. Consequently, phylib should not be matching this device. The only remaining way I can see that this could happen is if a PHY driver has an OF compatible, which phylib drivers should never have. -- RMK's Patch system: https://www.armlinux.org.uk/developer/patches/ FTTP is here! 40Mbps down 10Mbps up. Decent connectivity at last!