Re: [net-next: PATCH v2 4/7] net: mvmdio: simplify clock handling
From: Marcin Wojtas <hidden>
Date: 2021-06-16 23:25:55
Also in:
lkml
śr., 16 cze 2021 o 21:48 Andrew Lunn [off-list ref] napisał(a):
quoted
+ dev->clks[0].id = "core"; + dev->clks[1].id = "mg"; + dev->clks[2].id = "mg_core"; + dev->clks[3].id = "axi"; + ret = devm_clk_bulk_get_optional(&pdev->dev, MVMDIO_CLOCK_COUNT, + dev->clks);Kirkwood: mdio: mdio-bus@72004 { compatible = "marvell,orion-mdio"; #address-cells = <1>; #size-cells = <0>; reg = <0x72004 0x84>; interrupts = <46>; clocks = <&gate_clk 0>; status = "disabled"; Does this work? There is no clock-names in DT.
Neither are the clocks in Armada 7k8k / CN913x:
CP11X_LABEL(mdio): mdio@12a200 {
#address-cells = <1>;
#size-cells = <0>;
compatible = "marvell,orion-mdio";
reg = <0x12a200 0x10>;
clocks = <&CP11X_LABEL(clk) 1 9>,
<&CP11X_LABEL(clk) 1 5>,
<&CP11X_LABEL(clk) 1 6>,
<&CP11X_LABEL(clk) 1 18>;
status = "disabled";
};
Apparently I misread the code and got convinced that contrary to
devm_clk_get_optional(), the devm_clk_get_bulk_optional() obtains the
clocks directly by index, not name (on the tested boards, the same
clocks are enabled by the other interfaces, so the problems
I will drop this patch. Thank you for spotting the issue.
Best regards,
Marcin