Thread (10 messages) 10 messages, 5 authors, 2021-06-14

Re: [PATCH v2] net: phy: dp83867: perform soft reset and retain established link

From: Bajjuri, Praneeth <hidden>
Date: 2021-06-11 17:05:52
Also in: lkml

Hannes,

On 6/10/2021 12:53 AM, Johannes Pointner wrote:
Hello,

On Thu, Jun 10, 2021 at 6:10 AM Andrew Lunn [off-list ref] wrote:
quoted
On Wed, Jun 09, 2021 at 07:43:42PM -0500, praneeth@ti.com wrote:
quoted
From: Praneeth Bajjuri <redacted>

Current logic is performing hard reset and causing the programmed
registers to be wiped out.

as per datasheet: https://www.ti.com/lit/ds/symlink/dp83867cr.pdf
8.6.26 Control Register (CTRL)

do SW_RESTART to perform a reset not including the registers,
If performed when link is already present,
it will drop the link and trigger re-auto negotiation.

Signed-off-by: Praneeth Bajjuri <redacted>
Signed-off-by: Geet Modi <redacted>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>

     Andrew
I reported a few days ago an issue with the DP83822 which I think is
caused by a similar change.
https://lore.kernel.org/netdev/CAHvQdo2yzJC89K74c_CZFjPydDQ5i22w36XPR5tKVv_W8a2vcg@mail.gmail.com/ (local)
In my case I can't get an link after this change, reverting it fixes
the problem for me.
Are you saying that instead of reset if sw_restart is done as per this 
patch, there is no issue?
Hannes
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help