Even with CLK_BUS_EPHY/RST_BUS_EPHY enabled, the MAC reset timeout.
So no the CLK/RST are really for the PHY.
Thanks for trying that.
You said it was probably during scanning of the bus it times out. What
address is causing the timeout? 0 or 1? If the internal bus can only
have one PHY on it, maybe we need to set bus->phy_mask to 0x1?
Andrew
--
To unsubscribe from this list: send the line "unsubscribe devicetree" in
the body of a message to majordomo-u79uwXL29TY76Z2rM5mHXA@public.gmane.org