Thread (102 messages) 102 messages, 22 authors, 2013-12-01

Re: Triple parity and beyond

From: David Taylor <hidden>
Date: 2013-11-22 14:19:47

On Fri, 22 Nov 2013, Stan Hoeppner wrote:
With
any mirror based array one can lose half the disks as long as no two are
in one mirror.  The probability of a pair failing together is very low,
and this probability decreases even further as the number of drives in
the array increases.  This is one of the many reasons RAID 10 has been
so popular for so many years.
Er, no.

Sure, the probability of "the failed drive's pair" failing decreases
as the number of drives in the array increases IF you assume there will
be exactly one failure.

But adding more drives increases the probability of another drive
failure, and cancels that out.

Quite obviously adding more unrelated drives to an array does not
affect the probability of failure of the pre-existing drives!

(Except perhaps, by over-stressing the PSU and increasing the
chances of all the drives failing)

-- 
David Taylor 
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help