Hi Philipp,
On Wed, Jun 9, 2021 at 4:20 AM Philipp Zabel [off-list ref] wrote:
So now I wonder what happens between the first and second time (in
s_stream? in s_power(0)?) that does put the lanes into LP-11 from
whatever state they were in before. When you get the clock lane timeout,
is phy_state = 0x610? Does it stay there when you repeat this again?
Yes, correct. I do see phy_state = 0x610 in the second time I run the
Gstreamer pipeline:
New clock: GstSystemClock
[ 24.190274] imx6-mipi-csi2: clock lane timeout, phy_state = 0x00000610
[ 24.197737] ipu1_ic_prpvf: upstream stream on failed: -110
[ 24.204359] ipu1_ic_prpvf: pipeline start failed with -110
It stays there if I repeat it again.
Thanks,
Fabio Estevam