Re: [PATCH v5 2/7] can: bittiming: allow TDC{V,O} to be zero and add can_tdc_const::tdc{v,o,f}_min

From: Marc Kleine-Budde <mkl@pengutronix.de>
Date: 2021-08-16 08:42:45
Also in: lkml, netdev

On 15.08.2021 12:32:43, Vincent Mailhol wrote:
ISO 11898-1 specifies in section 11.3.3 "Transmitter delay
compensation" that "the configuration range for [the] SSP position
shall be at least 0 to 63 minimum time quanta."

Because SSP = TDCV + TDCO, it means that we should allow both TDCV and
TDCO to hold zero value in order to honor SSP's minimum possible
value.

However, current implementation assigned special meaning to TDCV and
TDCO's zero values:
  * TDCV = 0 -> TDCV is automatically measured by the transceiver.
  * TDCO = 0 -> TDC is off.

In order to allow for those values to really be zero and to maintain
current features, we introduce two new flags:
  * CAN_CTRLMODE_TDC_AUTO indicates that the controller support
    automatic measurement of TDCV.
  * CAN_CTRLMODE_TDC_MANUAL indicates that the controller support
    manual configuration of TDCV. N.B.: current implementation failed
    to provide an option for the driver to indicate that only manual
    mode was supported.

TDC is disabled if both CAN_CTRLMODE_TDC_AUTO and
CAN_CTRLMODE_TDC_MANUAL flags are off, c.f. the helper function
can_tdc_is_enabled() which is also introduced in this patch.
Nitpick: We can only say that TDC is disabled, if the driver supports
the TDC interface at all, which is the case if tdc_const is set.
Also, this patch adds three fields: tdcv_min, tdco_min and tdcf_min to
struct can_tdc_const. While we are not convinced that those three
fields could be anything else than zero, we can imagine that some
controllers might specify a lower bound on these. Thus, those minimums
are really added "just in case".
I'm not sure, if we talked about the mcp251xfd's tcdo, valid values are
-64...63.

Marc

-- 
Pengutronix e.K.                 | Marc Kleine-Budde           |
Embedded Linux                   | https://www.pengutronix.de  |
Vertretung West/Dortmund         | Phone: +49-231-2826-924     |
Amtsgericht Hildesheim, HRA 2686 | Fax:   +49-5121-206917-5555 |

Attachments

Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help