Thread (10 messages) 10 messages, 2 authors, 2011-02-08

Re: Read Characteristic Value vs. Read Long Characteristic Values

From: Brian Gix <hidden>
Date: 2011-01-25 19:46:25

Hi Anderson,

On Tue, 2011-01-25 at 15:07 -0400, Anderson Lizardo wrote:
Hi Brian,

On the implementation you did for Long Characteristic value read, you
integrated the Read Blob Request handling into the existing "Read
Characteristic Value" implementation. From my understanding of the
code, the read blob request is issued if the response PDU size is
greater than or equal to LE ATT_MTU (23).

The problem I see with this approach is that if the client knows that
the characteristic value is exactly 22 bytes (which makes total PDU
size equal to 23 with the opcode), a spurious read blob request (and
corresponding response) is sent. How could we avoid this overhead?

My idea was to separate the procedures, having a "Read Long
Characteristic Value" and revert Read Characteristic Value to read
only the first ATT_MTU - 1 bytes as before. For characteristic values
which the client knows to be within ATT_MTU - 1 bytes (of if it only
cares about these bytes at the time) it would use the latter. For
cases where value length is unknown, it would use the former.

This would also allow us to better map to GATT procedures and have
fine control on the client implementation and on our test tool
(igatttool).
quoted
From a practical perspective, the only attributes that would be
*exactly* 22 octets would be strings which defy attempts for a client to
predict their length without knowing what the content is ahead of time.

You are correct that if a *profile* defines a particular characteristic
attribute value to be exactly 22 octets, that this would result in
result it a harmless extra read.

For string reads this is not really a useless extra operation, because
it does supply definitive termination of the string, which per ATT
protocol cannot be provided any other way.

As far as test case coverage per the qualification test specification, I
do not believe that there is a problem.  Any non long "Reads" can be
tested by reading < 22 octet attributes, and long read tests by reading
= 22 octet attributes. 


-- 
Brian Gix
bgix@codeaurora.org
Employee of Qualcomm Innovation Center, Inc.
Qualcomm Innovation Center, Inc. is a member of Code Aurora Forum
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree