Re: Read Characteristic Value vs. Read Long Characteristic Values
From: Brian Gix <hidden>
Date: 2011-01-26 17:59:22
Hi Anderson, On Wed, 2011-01-26 at 09:58 -0400, Anderson Lizardo wrote:
On Wed, Jan 26, 2011 at 9:33 AM, Anderson Lizardo [off-list ref] wrote:quoted
Looks like more a PTS bug, but makes me wonder if it is not better for BlueZ to have separate procedures instead of this "automatic" usage of read blob request ?BTW, the test which presented this issue with sending spurious read blob request is named "Read Characteristic Descriptors – by client". I also can see that the behavior you implemented satisfies both "Read Long Characteristic Value - by client" and "Read Long Characteristic Descriptor - by client" tests. All theses tests come from the GATT TS document.
Can you tell me the specific Test Case number(s) that you are having difficulty testing? I do not have a current release of the PTS tool available to me at this time, although I do know that PTS is developed in parallel, and is just as prone to bugs as the rest of us. I should be able to test this stuff against the PTS guys at UPF week after next, and talk to the guys who are writing it. Thanks, -- Brian Gix bgix@codeaurora.org Employee of Qualcomm Innovation Center, Inc. Qualcomm Innovation Center, Inc. is a member of Code Aurora Forum