Thread (21 messages) 21 messages, 3 authors, 2026-03-25

Re: [PATCH v2 1/9] dt-bindings: display: rockchip: analogix-dp: Expand clock-names "hclk" for the third clock

From: Damon Ding <hidden>
Date: 2026-03-23 08:54:45
Also in: dri-devel, linux-devicetree, linux-rockchip, lkml

Hi Krzysztof,

On 3/20/2026 5:19 PM, Krzysztof Kozlowski wrote:
On Thu, Mar 19, 2026 at 06:40:23PM +0800, Damon Ding wrote:
quoted
The RK3588 eDP controller needs the video datapath clock "hclk" to work
well. Previously, it works without explicitly adding this clock because
the 'rockchip,vo-grf = <&vo1_grf>' property implicitly enables HCLK_VO1.

Fixes: f855146263b1 ("dt-bindings: display: rockchip: analogix-dp: Add support for RK3588")
Signed-off-by: Damon Ding <redacted>
---
  .../bindings/display/rockchip/rockchip,analogix-dp.yaml       | 4 +++-
  1 file changed, 3 insertions(+), 1 deletion(-)
diff --git a/Documentation/devicetree/bindings/display/rockchip/rockchip,analogix-dp.yaml b/Documentation/devicetree/bindings/display/rockchip/rockchip,analogix-dp.yaml
index d99b23b88cc5..d2bc8636b626 100644
--- a/Documentation/devicetree/bindings/display/rockchip/rockchip,analogix-dp.yaml
+++ b/Documentation/devicetree/bindings/display/rockchip/rockchip,analogix-dp.yaml
@@ -26,7 +26,9 @@ properties:
      items:
        - const: dp
        - const: pclk
-      - const: grf
+      - enum:
+          - grf
+          - hclk
You just told me it is the same clock, no? I asked that and you
confirmed? Or you replied with an answer not relevant to the question?
Aha, I may have misunderstood your earlier advice as meaning that since 
the RK3576 and RK3588 platforms share the same design, their clock 
dependencies should also be identical.

The 'grf' clock and 'hclk' clock are different.
On RK3399, the GRF clock is for accessing VIO GRF registers.
On RK3588/RK3576, the eDP 'hclk' is required as it is the parent clock 
of 'pclk' in the AHB bus topology.
If this device takes reference to grf, why does it also take grf clock?
Devices MUST NOT take clocks on behalf of other devices, so please
answer with a list of all clock inputs according to datasheet/manual.
On earlier platforms, the GRF was not partitioned into separate 
functional small GRF units as on newer designs. Therefore, the 'grf' 
clock was designed as the clock dependency for all relevant modules.

For RK3588/RK3576 eDP module, the list of all clock inputs is:

CLK_EDP0_24M: Reference clock.
PCLK_EDP0: AHB clock.
HCLK_VO1/HCLK_VO0_ROOT: Video datapath clock.

It would be better to add above comments as the descriptions of these 
clocks in yaml.

Best regards,
Damon
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree