On Wed, 17 Oct 2018 09:10:45 +0200
Boris Brezillon [off-list ref] wrote:
On Wed, 17 Oct 2018 09:07:24 +0200
Boris Brezillon [off-list ref] wrote:
quoted
On Wed, 17 Oct 2018 02:07:43 +0000
Yogesh Narayan Gaur [off-list ref] wrote:
quoted
quoted
Actually there is no entry of s25fs512s in current spi-nor.c file.
For my connected flash part, jedec ID read points to s25fl512s. I
have asked my board team to confirm the name of exact connected flash
part. When I check the data sheet of s25fs512s, it also points to the
same Jedec ID information. { "s25fl512s", INFO(0x010220, 0x4d00, 256
* 1024, 256, ....}
But as stated earlier, if I skip reading SFDP or read using 1-1-1
protocol then read are always correct. For 1-4-4 protocol read are
wrong and on further debugging found that Read code of 0x6C is being
send as opcode instead of 0xEC.
If I revert this patch, reads are working fine.
Can you try with the following patch?
Hm, nevermind. The problem is actually not related to 4B vs non-4B mode
but 1-1-4 vs 1-4-4 modes.
Can you try with this patch applied?
--->8---
diff --git a/drivers/mtd/spi-nor/spi-nor.c b/drivers/mtd/spi-nor/spi-nor.c
index 9407ca5f9443..cf33d834698c 100644
--- a/drivers/mtd/spi-nor/spi-nor.c
+++ b/drivers/mtd/spi-nor/spi-nor.c
@@ -3132,6 +3132,17 @@ static int spi_nor_parse_sfdp(struct spi_nor *nor,
switch (SFDP_PARAM_HEADER_ID(param_header)) {
case SFDP_SECTOR_MAP_ID:
err = spi_nor_parse_smpt(nor, param_header);
+ if (err) {
+ dev_warn(dev,
+ "failed to parse SMPT (err = %d)\n",
+ err);
+ /*
+ * SMPT parsing is optional, let's not drop
+ * all information we extracted so far just
+ * because it failed.
+ */
+ err = 0;
+ }
break;
default: