Thread (36 messages) 36 messages, 6 authors, 2015-08-18

3.18: lockdep problems in cpufreq

From: Yadwinder Singh Brar <hidden>
Date: 2014-12-15 14:54:05
Also in: linux-pm

-----Original Message-----
From: Russell King - ARM Linux [mailto:linux at arm.linux.org.uk]
Sent: Monday, December 15, 2014 7:17 PM
To: Yadwinder Singh Brar
Cc: 'Viresh Kumar'; 'Rafael J. Wysocki'; linux-arm-
kernel at lists.infradead.org; linux-pm at vger.kernel.org; 'Eduardo
Valentin'
Subject: Re: 3.18: lockdep problems in cpufreq

On Mon, Dec 15, 2014 at 06:58:41PM +0530, Yadwinder Singh Brar wrote:
quoted
Unfortunately, I didn?t get any such warning though I tested patch
enabling CONFIG_PROVE_LOCKING before posting. It seems Russell is
trying to load imx_thermal as module and parallely Changing cpufreq
governor from userspace, which was not my test case.
No.  Yes, imx_thermal is a module, which is loaded by udev very early
in the userspace boot.  Later on, in the rc.local, I poke the governor
from userspace.

This is evidenced by the bluetooth modules being loaded after
imx_thermal:

Module                  Size  Used by
bnep                   10574  2
rfcomm                 33720  0
bluetooth             293598  10 bnep,rfcomm
nfsd                   90264  0
exportfs                3988  1 nfsd
hid_cypress             1763  0
snd_soc_fsl_spdif       9753  2
imx_pcm_dma             1137  1 snd_soc_fsl_spdif
imx_sdma               12885  2
imx2_wdt                3248  0
imx_thermal             5386  0
snd_soc_imx_spdif       1877  0

and the timestamp on the bluetooth message:

[   25.503739] Bluetooth: Core ver 2.19

vs the timestamp on the lockdep message:

[   29.499195] [ INFO: possible circular locking dependency detected ]

My rc.local does this:

    # Configure cpufreq
    echo 1 > /sys/devices/system/cpu/cpufreq/ondemand/io_is_busy
    echo performance >
/sys/devices/system/cpu/cpu0/cpufreq/scaling_governor
quoted
Anyways, after analyzing log and code,I think problem is not in
cpufreq_thermal_notifier which was modified in patch as stated above.
Actual problem is in __cpufreq_cooling_register which is
unnecessarily
quoted
calling cpufreq_register_notifier() inside section protected by
cooling_cpufreq_lock.
Because cpufreq_policy_notifier_list).rwsem is already held by
store_scaling_governor when __cpufreq_cooling_register is trying to
cpufreq_policy_notifier_list while holding cooling_cpufreq_lock.

So I think following can fix the problem:
diff --git a/drivers/thermal/cpu_cooling.c
b/drivers/thermal/cpu_cooling.c index ad09e51..622ea40 100644
--- a/drivers/thermal/cpu_cooling.c
+++ b/drivers/thermal/cpu_cooling.c
@@ -484,15 +484,15 @@ __cpufreq_cooling_register(struct device_node
*np,
quoted
        cpufreq_dev->cpufreq_state = 0;
        mutex_lock(&cooling_cpufreq_lock);

-       /* Register the notifier for first cpufreq cooling device */
-       if (cpufreq_dev_count == 0)
-
cpufreq_register_notifier(&thermal_cpufreq_notifier_block,
quoted
-                                         CPUFREQ_POLICY_NOTIFIER);
        cpufreq_dev_count++;
        list_add(&cpufreq_dev->node, &cpufreq_dev_list);

        mutex_unlock(&cooling_cpufreq_lock);

+       /* Register the notifier for first cpufreq cooling device */
+       if (cpufreq_dev_count == 0)
+
cpufreq_register_notifier(&thermal_cpufreq_notifier_block,
quoted
+                                         CPUFREQ_POLICY_NOTIFIER);
No, sorry, this patch is worse.
Actually it was not patch :P , just moved cpufreq_register_notifier()
out of locking, as it is(C&P) to explain my point.
1. cpufreq_register_notifier() will never be called, even on the first
   caller to this code: at the point where it's tested for zero, it
will
   be incremented to one by the previous code.

2. What happens if two threads come here?

   The first thread succeeds in grabbing cooling_cpufreq_lock.  The
second
   thread stalls waiting for cooling_cpufreq_lock to be released.

   The first thread increments cpufreq_dev_count, adds to the list, and
then
   releases the lock.  At this point, control may be passed to the
second
   thread (since mutex_unlock() will wake it up.)  The second thread
gets
   into the critical region, and increments cpufreq_dev_count again.

   By the time the first thread runs, cpufreq_dev_count may be two at
this
   point.
Yes, may be.
Unfortunately, you do need some kind of synchronisation here.  If it's
not important when cpufreq_register_notifier() gets called, maybe this
can work:

	bool register;

	mutex_lock(&cooling_cpufreq_lock);
	register = cpufreq_dev_count++ == 0;
	list_add(&cpufreq_dev->node, &cpufreq_dev_list);
	mutex_unlock(&cooling_cpufreq_lock);

	if (register)
register may be 0 in scenario you stated above in second point.
So this approach will not work.
 
		cpufreq_register_notifier(&thermal_cpufreq_notifier_block,
					  CPUFREQ_POLICY_NOTIFIER);

However, I suspect that may well be buggy if we have a cleanup path
which unregisters the notifier when cpufreq_dev_count is decremented to
zero...
which we seem to have in cpufreq_cooling_unregister().

The answer may well be to have finer grained locking here:

- one lock to protect cpufreq_dev_list, which is only ever taken when
  adding or removing entries from it

- a second lock to protect cpufreq_dev_count and the calls to
  cpufreq_register_notifier() and cpufreq_unregister_notifier()

and you would /never/ take either of those two locks inside each other.
In other words:

	mutex_lock(&cooling_list_lock);
	list_add(&cpufreq_dev->node, &cpufreq_dev_list);
	mutex_unlock(&cooling_list_lock);

	mutex_lock(&cooling_cpufreq_lock);
	if (cpufreq_dev_count++ == 0)
		cpufreq_register_notifier(&thermal_cpufreq_notifier_block,
					  CPUFREQ_POLICY_NOTIFIER);
	mutex_unlock(&cooling_cpufreq_lock);

and similar in the cleanup path.  The notifier itself would only ever
take the cooling_list_lock.
I agree with this approach, if its fine for others also, I can implement
and post patch.

Thanks,
Yadwinder
--
FTTC broadband for 0.8mile line: currently at 9.5Mbps down 400kbps up
according to speedtest.net.
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help