On 06/18/2012 11:54 AM, Marc Kleine-Budde wrote:
quoted
Also ge-phy has to be connected with ge-clk, too. But for dove this is a clk gate while kirkwood can shut it down somewhere else. I guess it can be handled like sata/pcie on kirkwood.The PHY is a clock gate so I'm handling it via:quoted
ge = dove_register_gate("ge0", CLOCK_GATING_GBE_BIT | CLOCK_GATING_GIGA_PHY_BIT);So no gate_fn needed.
There is no fn needed for dove, but kirkwood will need one IIRC. Moreover, you could hook-up PHY-gate as a parent of corresponding clk-gate and they will be enabled/disabled simultaneously. But I'd prefer the driver to take care of clks _and_ PHYs. One more: I suggest to clean the clk names of orion platforms, they are a mess ;) And IMHO clks should always have both strings set, e.g. kirkwood-i2s has an extclk input besides it on-chip clk. Sebastian