Thread (3 messages) flat view 3 messages, 2 authors, 2022-08-23

Re: [PATCH 1/2] net: mt7531: only do PLL once after the reset

From: Paolo Abeni <pabeni@redhat.com>
Date: 2022-08-23 14:06:06
Also in: linux-mediatek, lkml

On Sat, 2022-08-20 at 23:37 +0200, Alexander Couzens wrote:
Move the PLL init of the switch out of the pad configuration of the port
6 (usally cpu port).

Fix a unidirectional 100 mbit limitation on 1 gbit or 2.5 gbit links for
outbound traffic on port 5 or port 6.

Signed-off-by: Alexander Couzens <lynxis@fe80.eu>
This (and the next patch) looks like a fix suitable for -net. Could you
please re-post, targeting the appropriate tree and more importantly
including a 'Fixes' tag in the commit message of each patch?

Thanks!

Paolo