From: Yevgeny Kliteynik <redacted>
On BlueField the E-Switch manager is the ECPF (vport 0xFFFE), but when
querying capabilities of ECPF eswitch manager, need to query vport 0
with other_vport = 0.
Fixes: 9091b821aaa4 ("net/mlx5: DR, Handle eswitch manager and uplink vports separately")
Signed-off-by: Yevgeny Kliteynik <redacted>
Reviewed-by: Alex Vesker <redacted>
Signed-off-by: Saeed Mahameed <saeedm@nvidia.com>
---
drivers/net/ethernet/mellanox/mlx5/core/steering/dr_domain.c | 4 +---
1 file changed, 1 insertion(+), 3 deletions(-)
diff --git a/drivers/net/ethernet/mellanox/mlx5/core/steering/dr_domain.c b/drivers/net/ethernet/mellanox/mlx5/core/steering/dr_domain.c
index f6e6d9209766..c54cc45f63dc 100644
--- a/drivers/net/ethernet/mellanox/mlx5/core/steering/dr_domain.c
+++ b/drivers/net/ethernet/mellanox/mlx5/core/steering/dr_domain.c
@@ -164,9 +164,7 @@ static int dr_domain_query_vport(struct mlx5dr_domain *dmn,
static int dr_domain_query_esw_mngr(struct mlx5dr_domain *dmn)
{
- return dr_domain_query_vport(dmn,
- dmn->info.caps.is_ecpf ? MLX5_VPORT_ECPF : 0,
- false,
+ return dr_domain_query_vport(dmn, 0, false,
&dmn->info.caps.vports.esw_manager_caps);
}
--
2.33.1