On 12/7/21 11:32, Russell King (Oracle) wrote:
Maarten Zanders has confirmed that the issue he was addressing was for
an 88E6250 switch, which does not have a PHY_DETECT bit in bit 12, but
instead a link status bit. Therefore, mv88e6xxx_port_ppu_updates() does
not report correctly.
...> Yes, you're right, I'm targeting the 6250 family. And yes, your
suggestion would solve my case and is a better implementation for
the other devices (as far as I can see).
I confirm that this patch works on my hardware, which uses an 88E6071 (88E6250 family).