Thread (2 messages) 2 messages, 2 authors, 2021-07-06
STALE1797d LANDED

[PATCH net] can: j1939: j1939_xtp_rx_dat_one(): fix rxtimer value between consecutive TP.DT to 750ms

From: Zhang Changzhong <hidden>
Date: 2021-07-06 10:54:03
Also in: linux-can, lkml
Subsystem: can network layer, can-j1939 network layer, the rest · Maintainers: Oliver Hartkopp, Marc Kleine-Budde, Robin van der Gracht, Oleksij Rempel, Linus Torvalds

For receive side, the max time interval between two consecutive TP.DT
should be 750ms.

Fixes: 9d71dd0c7009 ("can: add support of SAE J1939 protocol")
Signed-off-by: Zhang Changzhong <redacted>
---
 net/can/j1939/transport.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/net/can/j1939/transport.c b/net/can/j1939/transport.c
index c3946c3..4113229 100644
--- a/net/can/j1939/transport.c
+++ b/net/can/j1939/transport.c
@@ -1869,7 +1869,7 @@ static void j1939_xtp_rx_dat_one(struct j1939_session *session,
 		if (!session->transmission)
 			j1939_tp_schedule_txtimer(session, 0);
 	} else {
-		j1939_tp_set_rxtimeout(session, 250);
+		j1939_tp_set_rxtimeout(session, 750);
 	}
 	session->last_cmd = 0xff;
 	consume_skb(se_skb);
-- 
2.9.5