Thread (2 messages) 2 messages, 2 authors, 2021-07-06

Re: [PATCH net] can: j1939: j1939_xtp_rx_dat_one(): fix rxtimer value between consecutive TP.DT to 750ms

From: Oleksij Rempel <o.rempel@pengutronix.de>
Date: 2021-07-06 12:19:48
Also in: linux-can, lkml

On Tue, Jul 06, 2021 at 07:00:08PM +0800, Zhang Changzhong wrote:
For receive side, the max time interval between two consecutive TP.DT
should be 750ms.

Fixes: 9d71dd0c7009 ("can: add support of SAE J1939 protocol")
Signed-off-by: Zhang Changzhong <redacted>
ACK,
according to: SAE-J1939-21: T1 time is 750ms
according to: ISO 11783-3: T1 time is <=750ms

Acked-by: Oleksij Rempel <o.rempel@pengutronix.de>
quoted hunk ↗ jump to hunk
---
 net/can/j1939/transport.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/net/can/j1939/transport.c b/net/can/j1939/transport.c
index c3946c3..4113229 100644
--- a/net/can/j1939/transport.c
+++ b/net/can/j1939/transport.c
@@ -1869,7 +1869,7 @@ static void j1939_xtp_rx_dat_one(struct j1939_session *session,
 		if (!session->transmission)
 			j1939_tp_schedule_txtimer(session, 0);
 	} else {
-		j1939_tp_set_rxtimeout(session, 250);
+		j1939_tp_set_rxtimeout(session, 750);
 	}
 	session->last_cmd = 0xff;
 	consume_skb(se_skb);
-- 
2.9.5

-- 
Pengutronix e.K.                           |                             |
Steuerwalder Str. 21                       | http://www.pengutronix.de/  |
31137 Hildesheim, Germany                  | Phone: +49-5121-206917-0    |
Amtsgericht Hildesheim, HRA 2686           | Fax:   +49-5121-206917-5555 |
Keyboard shortcuts
hback out one level
jnext message in thread
kprevious message in thread
ldrill in
Escclose help / fold thread tree
?toggle this help