On Fri, Jun 18, 2021 at 6:35 PM Jakub Kicinski [off-list ref] wrote:
Like all legacy SR-IOV networking the correct thing to do here is clear
as mud. I'd go for the link status of the PF netdev. If the netdev
cannot pass traffic (either for administrative or physical link reasons)
then VFs shouldn't talk either. But as I said, every vendor will have their
own interpretation, and different users may expect different things...
On Fri, Jun 18, 2021 at 9:10 PM Keller, Jacob E
[off-list ref] wrote:
I like this interpretation too.. but I agree that it's unfortunately confusing and each vendor has done something different.. :(
Thanks Jakub and Keller, at least now it's clear that it's not clear :P
Good enough info to move forward, for me.
--
Íñigo Huguet