Re: [PATCH] phy: maxlinear: add Maxlinear GPY115/21x/24x driver
From: Liang Xu <lxu@maxlinear.com>
Date: 2021-06-01 17:14:10
On 2/6/2021 12:55 am, Andrew Lunn wrote:
This email was sent from outside of MaxLinear.quoted
quoted
quoted
+ linkmode_mod_bit(ETHTOOL_LINK_MODE_5000baseT_Full_BIT, + phydev->supported, + ret & MDIO_PMA_NG_EXTABLE_5GBT); +Does genphy_c45_pma_read_abilities() do the wrong thing here? What does it get wrong?The problem comes from condition "phydev->c45_ids.mmds_present & MDIO_DEVS_AN". Our product supports both C22 and C45. In the real system, we found C22 was used by customers (with indirect access to C45 registers when necessary). Then during probe, in API "get_phy_device", it skips reading C45 IDs. So that genphy_c45_pma_read_abilities skip the supported flag ETHTOOL_LINK_MODE_Autoneg_BIT.This sounds like a generic problem, which will affect any PHY which has both C22 and C45. I wounder if it makes sense to add a helper function which a PHY driver can call to get the phydev->c45_ids.mmds_present populated?
I thought to use get_phy_c45_ids in gpy_config_init to populate the c45_ids, but this is a static function inside phy_device.c. Or maybe in genphy_c45_pma_read_abilities, it reads MII_BMSR register if is_c45 not set.
quoted
quoted
quoted
+static int gpy_read_status(struct phy_device *phydev) +{ + int ret; + + ret = genphy_update_link(phydev); + if (ret) + return ret; + + phydev->speed = SPEED_UNKNOWN; + phydev->duplex = DUPLEX_UNKNOWN; + phydev->pause = 0; + phydev->asym_pause = 0; + + if (phydev->autoneg == AUTONEG_ENABLE && phydev->autoneg_complete) { + ret = genphy_c45_read_lpa(phydev); + if (ret < 0) + return ret; + + /* Read the link partner's 1G advertisement */ + ret = phy_read(phydev, MII_STAT1000); + if (ret < 0) + return ret; + mii_stat1000_mod_linkmode_lpa_t(phydev->lp_advertising, ret);can genphy_read_lpa() be used here?2.5G is not covered in genphy_read_lpa. If I use genphy_c45_read_lpa first then genphy_read_lpa after, it seems a bit redundant.I'm just trying to avoid repeating code which is in helpers. I think this is the first PHY driver which uses a mixture of C22 and C45 like this. So it could be the helpers need small modifications to make them work. We should make those modifications, since your PHY is not likely to be the only mixed C22 and C45 device.
I agree, this is issue for mixed C22/45 device. I saw something similar in BRCM driver (bcm84881_read_status) and Marvell driver (mv3310_read_status_copper). They are C45 device and use vendor specific register in MMD to access C22 equivalent registers.
Andrew