Thread (59 messages) flat view 59 messages, 6 authors, 2018-03-14

Re: [PATCH v4 2/2] virtio_net: Extend virtio to use VF datapath when available

From: "Michael S. Tsirkin" <mst@redhat.com>
Date: 2018-03-07 02:38:54

On Tue, Mar 06, 2018 at 03:27:46PM -0800, Alexander Duyck wrote:
quoted
I definitelly vote for a separate common shared code for both netvsc and
virtio_net - even if you use 2 and 3 netdev model, you could share the
common code. Strict checks and limitation should be in place.
Noted. But as I also mentioned there isn't that much "common" code
between the two models. I think if anything we could probably look at
peeling out a few bits such as "get_<iface>_bymac" which really would
become dev_get_by_mac_and_ops in order to find the device for the
notifiers. I probably wouldn't even put that in our driver and would
instead put it in the core code since it almost makes more sense
there. Beyond that sharing becomes much more challenging due to the
differences in the Rx and Tx paths that build out of the difference
between the 2 driver and 3 driver models.
At this point it might be worth it to articulate the advantages
of the 3 netdev model.

If they are compelling, why wouldn't netvsc users want them?

Alex, I think you were one of the strongest proponents of this model,
you should be well placed to provide a summary.

-- 
MST