Thread (26 messages) flat view 26 messages, 6 authors, 2017-10-26

Re: [Intel-wired-lan] [jkirsher/next-queue PATCH v4 6/6] i40e: Enable cloud filters via tc-flower

From: Nambiar, Amritha <hidden>
Date: 2017-10-26 21:47:08
Also in: intel-wired-lan

On 10/26/2017 2:35 PM, Shannon Nelson wrote:
On 10/26/2017 2:29 PM, Nambiar, Amritha wrote:
quoted
On 10/11/2017 4:30 PM, Shannon Nelson wrote:
quoted
On 10/10/2017 5:24 PM, Amritha Nambiar wrote:
[...]
quoted
quoted
quoted
+		/* For Geneve, the VNI should be placed in offset shifted by a
+		 * byte than the offset for the Tenant ID for rest of the
This comment isn't quite clear - maybe s/than/then/ ?
How about, "For Geneve, the VNI should begin at an offset shifted by a
byte compared to the offset normally used for the Tenant ID for other
tunnel types" ?
Or maybe "Due to hardware eccentricities, the VNI for Geneve is shifted 
one more byte further than normally used for Tenant ID in other tunnel 
types"
Will do. Thanks.
[...]
quoted
quoted
quoted
+				dev_err(&pf->pdev->dev, "Bad src port mask 0x%04x\n",
Consider using %pI4
For ports, I'll keep the 0x%04x. I'll change to %pI4 for the IPv4
address masks.
Oh, right, that one's a port.

sln