Thread (13 messages) 13 messages, 4 authors, 2015-03-10

Re: If bridge have no sub-interfaces, it's status may be still with 'RUNNING'

flat view

From: Stephen Hemminger <stephen@networkplumber.org>
Date: 2015-02-16 16:52:17

On Mon, 16 Feb 2015 12:55:47 +0800
yzhu1 [off-list ref] wrote:
Hi, Stephen

Follow your advice, I made a new patch. This patch will turn off
carrier when a new bridge interface is created. Please comment on it.

Thanks a lot.
Zhu Yanjun
NAK.
We need to keep the current behavior to not break corner case users.