Re: [PATCH 06/14] net: dsa: Add support for hardware monitoring
From: Guenter Roeck <linux@roeck-us.net>
Date: 2014-10-23 17:39:04
Also in:
lkml
On Thu, Oct 23, 2014 at 06:54:59PM +0200, Andrew Lunn wrote:
On Thu, Oct 23, 2014 at 09:27:55AM -0700, Guenter Roeck wrote:quoted
On Thu, Oct 23, 2014 at 03:47:06PM +0200, Andrew Lunn wrote:quoted
quoted
quoted
quoted
+static DEVICE_ATTR_RO(temp1_input);You probably want the number of temperature sensors to come from the switch driver, and support arbitrary number of temperature sensors?In that case we would need the number of sensors, pass a sensor index, and create a dynamic number of attributes. The code would get much more complex without real benefit unless there is such a chipWe are two different use cases here: One switch chip with multiple temperature sensorsI understand this case. However, quite frankly, I consider this quite unlikely to happen.quoted
Multiple switch chips, each with its own temperature sensor.I don't really see the problem. My understanding is that each of those switch chips will instantiate itself, dsa_switch_setup will be called, which will create a new hwmon device with its own sensors. That is how all other hwmon devices do it, and it works just fine. Why would that approach not work for switches in the dsa infrastructure ? Am I missing something ? If the concern or assumption is that there can not be more than one "temp1_input" attribute, here is an example from a system with a large number of chips with temperature sensors. root@evo-xb49:/sys/class/hwmon# ls hwmon*/temp1_input hwmon1/temp1_input hwmon22/temp1_input hwmon35/temp1_input hwmon10/temp1_input hwmon23/temp1_input hwmon36/temp1_input hwmon11/temp1_input hwmon24/temp1_input hwmon37/temp1_input hwmon12/temp1_input hwmon25/temp1_input hwmon38/temp1_input hwmon13/temp1_input hwmon26/temp1_input hwmon39/temp1_input hwmon14/temp1_input hwmon27/temp1_input hwmon4/temp1_input hwmon15/temp1_input hwmon28/temp1_input hwmon40/temp1_input hwmon16/temp1_input hwmon29/temp1_input hwmon5/temp1_input hwmon17/temp1_input hwmon3/temp1_input hwmon6/temp1_input hwmon18/temp1_input hwmon30/temp1_input hwmon7/temp1_input hwmon19/temp1_input hwmon31/temp1_input hwmon8/temp1_input hwmon2/temp1_input hwmon32/temp1_input hwmon9/temp1_input hwmon20/temp1_input hwmon33/temp1_input hwmon21/temp1_input hwmon34/temp1_inputSo are you saying it is impossible to map a hwmon device to a physical sensor? I can know there is a hotspot somewhere in my machine, but it is impossible to figure where that hot spot is using hwmon?
No, I am not saying that. The hwmon device's parent device will tell, which is how it works for all other hwmon devices.
quoted
quoted
If we are not doing the generic implementation now, how about avoiding an ABI break in the future, by hard coding the sensors with .0.0 on the end?I am a little lost. What would that be for, and what would the ABI breakage be ?I assumed you would want to be able to map a temperature sensor to a switch package. You want a unique identifier, maybe its hwman name? So name "dsa.0.0" would be the temperature sensor 0 on switch 0. If we don't name them like this now, whenever somebody does add support for this will cause that name to change and we have an ABI break.
Not really. Again, the parent device provides that information. libsensors, which is the preferred way of accessing sensors information from user space, provides the parent device instance as part of the logical sensor device name. In this case, the names will end up being dsa-isa-0000, dsa-isa-0001, and so on. With your added tags it would be dsa.0.0-isa-0000, dsa.0.1-isa-0001, and so on. I don't see how this would add any value. Also, temperature sensor 2 on switch 1 would be named temp2_input. There would not be a sepate hwmon device for the same chip. This is all quite similar to, say, the CPU temperature, which is reported by the sensors command as coretemp-isa-0000 Adapter: ISA adapter Physical id 0: +28.0°C (high = +80.0°C, crit = +100.0°C) Core 0: +28.0°C (high = +80.0°C, crit = +100.0°C) Core 1: +24.0°C (high = +80.0°C, crit = +100.0°C) Core 2: +24.0°C (high = +80.0°C, crit = +100.0°C) Core 3: +26.0°C (high = +80.0°C, crit = +100.0°C) on my system at home. The raw data in this case is name:coretemp temp1_crit:100000 temp1_crit_alarm:0 temp1_input:31000 temp1_label:Physical id 0 temp1_max:80000 temp2_crit:100000 temp2_crit_alarm:0 temp2_input:31000 temp2_label:Core 0 temp2_max:80000 temp3_crit:100000 temp3_crit_alarm:0 temp3_input:26000 temp3_label:Core 1 temp3_max:80000 temp4_crit:100000 temp4_crit_alarm:0 temp4_input:24000 temp4_label:Core 2 temp4_max:80000 temp5_crit:100000 temp5_crit_alarm:0 temp5_input:27000 temp5_label:Core 3 temp5_max:80000 In this case, the parent device symlink is device -> ../../../coretemp.0 A second CPU in a multi-CPU server system would have pretty much the same information in its hwmon device directory, except that the parent device would point to coretemp.1, and the sensors command would display "coretemp-isa-0001". The "name" attribute for that second CPU's hwmon device node would still be "coretemp". Thanks, Guenter