RE: Atheros Communications Inc. AR8121/AR8113/AR8114 Gigabit or Fast Ethernet (rev b0) 1.0.0.7 md5/sha1 corrupted using NFS and samba (updated) Version 2
From: Huang, Xiong <hidden>
Date: 2013-03-26 04:44:51
From: Huang, Xiong <hidden>
Date: 2013-03-26 04:44:51
You can try to get windows register setting by Pci config space register 0x80/0x84 For example, to read register 0x1480 Pci configure write 0x1480 to [0x80] (32bit) Pci configure read [0x84] Only 32 bit read/write is allowed. Thanks Xiong
-----Original Message----- From: Hannes Frederic Sowa [mailto:hannes@stressinduktion.org] Sent: Tuesday, March 26, 2013 12:40 PM To: Huang, Xiong Cc: Sven Hartge; netdev@vger.kernel.org Subject: Re: Atheros Communications Inc. AR8121/AR8113/AR8114 Gigabit or Fast Ethernet (rev b0) 1.0.0.7 md5/sha1 corrupted using NFS and samba (updated) Version 2 On Tue, Mar 26, 2013 at 04:34:36AM +0000, Huang, Xiong wrote:quoted
Are you sure the NIC is ok for windows driver ? it might be an HW bug, if it’sthe case, your checksum verificated by protocol is a workaround. Yes, the NIC is ok in Windows.