On P1022DS both ethernet controllers are connected to RGMII PHYs
accessible via MDIO bus. Remove fixed-link property from ethernet
nodes as they only required when fixed link PHYs without MDIO bus
are used.
Signed-off-by: Felix Radensky <redacted>
---
arch/powerpc/boot/dts/p1022ds.dts | 2 --
1 files changed, 0 insertions(+), 2 deletions(-)
diff --git a/arch/powerpc/boot/dts/p1022ds.dts b/arch/powerpc/boot/dts/p1022ds.dts
index 98d9426..1be9743 100644
--- a/arch/powerpc/boot/dts/p1022ds.dts
+++ b/arch/powerpc/boot/dts/p1022ds.dts
@@ -412,7 +412,6 @@
fsl,magic-packet;
fsl,wake-on-filer;
local-mac-address = [ 00 00 00 00 00 00 ];
- fixed-link = <1 1 1000 0 0>;
phy-handle = <&phy0>;
phy-connection-type = "rgmii-id";
queue-group@0{@@ -439,7 +438,6 @@
fsl,num_rx_queues = <0x8>;
fsl,num_tx_queues = <0x8>;
local-mac-address = [ 00 00 00 00 00 00 ];
- fixed-link = <1 1 1000 0 0>;
phy-handle = <&phy1>;
phy-connection-type = "rgmii-id";
queue-group@0{--
1.7.4.4