Thread (25 messages) 25 messages, 6 authors, 2024-01-24

Re: [PATCH v3 5/5] serial: 8250_dw: add em485 support

From: Giulio Benetti <hidden>
Date: 2021-02-05 18:55:14
Also in: lkml

Il 02/02/2021 12:22, Andy Shevchenko ha scritto:
On Tue, Feb 02, 2021 at 01:31:17AM +0100, Giulio Benetti wrote:
quoted
Il 18/05/2020 17:21, Andy Shevchenko ha scritto:
quoted
On Sun, May 17, 2020 at 11:56:10PM +0200, Heiko Stuebner wrote:
quoted
From: Giulio Benetti <redacted>

Need to use rs485 transceiver so let's use existing em485 485 emulation
layer on top of 8250.

Add rs485_config callback to port and uses the standard em485 start and
stop helpers.
Would it prevent to use native RS485 support?
8250_dw doesn't have a native RS485 support, do you mean using hardware
RTS assertion? Anyway at the moment it's not present. This would be the
first rs485 support added to 8250_dw.
DW v4.0+ has it.
I have access to datasheet of DW v3, and I don't have access to hardware
with DW v4.0v Uart.
But I could add rs485emu for only UART version < 4.0 and I can find Uart
version by reading UCV register, would it be acceptable?

Best regards
-- 
Giulio Benetti
CTO

MICRONOVA SRL
Sede: Via A. Niedda 3 - 35010 Vigonza (PD)
Tel. 049/8931563 - Fax 049/8931346
Cod.Fiscale - P.IVA 02663420285
Capitale Sociale € 26.000 i.v.
Iscritta al Reg. Imprese di Padova N. 02663420285
Numero R.E.A. 258642