Thread (25 messages) 25 messages, 6 authors, 2024-01-24

Re: [PATCH v3 5/5] serial: 8250_dw: add em485 support

From: Giulio Benetti <hidden>
Date: 2021-02-02 00:32:09
Also in: lkml

Hi Andy,

Il 18/05/2020 17:21, Andy Shevchenko ha scritto:
On Sun, May 17, 2020 at 11:56:10PM +0200, Heiko Stuebner wrote:
quoted
From: Giulio Benetti <redacted>

Need to use rs485 transceiver so let's use existing em485 485 emulation
layer on top of 8250.

Add rs485_config callback to port and uses the standard em485 start and
stop helpers.
Would it prevent to use native RS485 support?
8250_dw doesn't have a native RS485 support, do you mean using hardware
RTS assertion? Anyway at the moment it's not present. This would be the
first rs485 support added to 8250_dw.

Best regards
-- 
Giulio Benetti
CTO

MICRONOVA SRL
Sede: Via A. Niedda 3 - 35010 Vigonza (PD)
Tel. 049/8931563 - Fax 049/8931346
Cod.Fiscale - P.IVA 02663420285
Capitale Sociale € 26.000 i.v.
Iscritta al Reg. Imprese di Padova N. 02663420285
Numero R.E.A. 258642
...
quoted
  	p->serial_out	= dw8250_serial_out;
  	p->set_ldisc	= dw8250_set_ldisc;
  	p->set_termios	= dw8250_set_termios;
+	p->rs485_config = serial8250_em485_config;
+	up->rs485_start_tx = serial8250_em485_start_tx;
+	up->rs485_stop_tx = serial8250_em485_stop_tx;
  