On 15 Jan 2007, Bill Davidsen told this:
Nix wrote:
quoted
Number Major Minor RaidDevice State
0 8 6 0 active sync /dev/sda6
1 8 22 1 active sync /dev/sdb6
3 22 5 2 active sync /dev/hdc5
Number Major Minor RaidDevice State
0 8 23 0 active sync /dev/sdb7
1 8 7 1 active sync /dev/sda7
3 3 5 2 active sync /dev/hda5
0, 1, and *3*. Where has number 2 gone? (And how does `Number' differ
from `RaidDevice'? Why have both?)
Did you ever move the data to these drives from another? I think this
is what you see when you migrate by adding a drive as a spare, then
mark an existing drive as failed, so the data is rebuilt on the new
drive. Was there ever a device 2?
Nope. These arrays were created in one lump and never had a spare.
Plenty of pvmoves have happened on them, but that's *inside* the
arrays, of course...
--